[Contents] [Prev] [Next] [Index] [Report an Error]


Monitoring Redundant SSBs

You monitor redundant M20 router System and Switch Boards (SSBs) to ensure that they do the following (see Table 127):


Table 127: Checklist for Monitoring Redundant SSBs
Monitor Redundant SSB Tasks
Command or Action

configure
show

show chassis hardware

  1. Display the Redundant SSB Environmental Status

show chassis environment

  1. Display the Redundant SSB Detailed Status

show chassis ssb slot

  1. Check the Redundant SSB LEDs

Check the LEDs on the SSB faceplate.

  1. Display SSB Mastership from the Command Line

show chassis ssb

  1. Check the SSB Mastership from the LEDs

Check the LEDs on the SSB panel of the craft interface.

  1. Display the Current SSB Alarms

show chassis alarms

  1. Display SSB Error Messages in the System Log File

show log messages

  1. Display SSB Error Messages in the Chassis Daemon Log File

show log chassisd

  1. Check the SSB Connection

Check the thumbscrews on the left and right sides of the SSB.

  1. Perform a Swap Test on the SSB
  1. Take the SSB offline.
  2. Remove the SSB.
  3. Replace the SSB with one that you know works.
  4. Verify that the new SSB works by using the show chassis ssb CLI command.

request chassis ssb master switch <no-confirm>

  1. Take the SSB offline.
  2. Remove the SSB.
  3. Install a new SSB.
  4. Verify that the new SSB works by using the show chassis ssb CLI command.


[Contents] [Prev] [Next] [Index] [Report an Error]