Displaying SIB Redundancy Information
Action
To display the redundant SIB state, use the following CLI command:
user@host>show chassis sibSample Output
t320@host>show chassis sibsSlot State Uptime0 Spare1 Online 2 days, 7 hours, 10 minutes, 13 seconds2 Online 2 days, 7 hours, 10 minutes, 13 secondst640@host>show chassis sibsSlot State Uptime0 Spare1 Online 4 hours, 5 minutes, 47 seconds2 Online 4 hours, 5 minutes, 42 seconds3 Online 4 hours, 5 minutes, 37 seconds4 Online 4 hours, 5 minutes, 33 secondsWhat it Means
The command output is for a T320 router and a T640 routing node. On the T320 router,
SIB1andSIB2are active (Online), whileSIB0is backup (Spare). On the T640 routing node,SIB1,SIB2,SIB3, andSIB4are active, whileSIB0is the backup. The possible states areSpare, Online,Offline, orEmpty. The command output also displays how long each SIB has been online in hours, minutes, and seconds.Alternative Action
You can also view redundant SIB status by using the following CLI command:
user@host>show chassis environment sibuser@host> show chassis environment sibSIB 0 status:State SpareTemperature 44 degrees C / 111 degrees FPower:GROUND 0 mV1.8 V 1807 mV2.5 V 2478 mV3.3 V 3308 mV1.8 V bias 1797 mV3.3 V bias 3284 mV5.0 V bias 5018 mV8.0 V bias 7440 mVSIB 1 status:State OnlineTemperature 50 degrees C / 122 degrees FPower:GROUND 0 mV1.8 V 1814 mV2.5 V 2485 mV1.8 V bias 1794 mV3.3 V bias 3313 mV5.0 V bias 5028 mV8.0 V bias 7553 mVSIB 2 status:[...Output truncated...]SIB 3 status:[...Output truncated...]SIB 4 status:[...Output truncated...]The command output displays the SIB slot, status, and the temperature of the air flowing past the SPP card and the power source information. Notice that
SIB0status is displayed asSpare, or backup.You can display the environmental status of a particular SIB with the following CLI command:
user@host>show chassis environment sibslot