Step 1: Monitor the Redundant SCG Environmental Status
Action
To check the redundant SCG environment status, use the following CLI command:
user@host>show chassis environmentSample Output
t320@host> show chassis environmentClass Item Status MeasurementPower PEM 0 AbsentPEM 1 OKTemp SCG 0 OK 30 degrees C / 86 degrees FSCG 1 OK 29 degrees C / 84 degrees F[...Output truncated...]What It Means
The command output displays the status and temperature for each SCG.
Alternative Action
If there is a problem with the SCG status, you can display more detailed SCG environmental information with the following CLI command:
user@host>show chassis environment scgThe command output is as follows:
t320@host> show chassis environment scgSCG 0 status:State Online - Master clockTemperature 30 degrees C / 86 degrees FPower:GROUND 0 mV3.3 V 3317 mV5.0 V 5072 mV5.6 V 5697 mV1.8 V bias 1794 mV3.3 V bias 3304 mV5.0 V bias 4991 mV8.0 V bias 7318 mVBUS Revision 40SCG 1 status:State Online - StandbyTemperature 29 degrees C / 84 degrees FPower:GROUND 0 mV3.3 V 3318 mV5.0 V 5084 mV5.6 V 5704 mV1.8 V bias 1782 mV3.3 V bias 3286 mV5.0 V bias 5003 mV8.0 V bias 7323 mVBUS Revision 40The command output displays the status for each SCG slot 0 and 1. The operating status can be
Present,Online,Offline, orEmpty. IfOnline, it can be the clock source (Master clock) or backup (Standby). As shown in the output, the redundant SCG isSCG1, with a status ofStandby. The command output displays the temperature of the air flowing past the SCG. The command output also displays information about the SCG power supplies and the SCG circuitry revision level.