Performing a Swap Test on a Redundant SCG
Action
To perform a swap test on a redundant SCG, follow these steps:
user@host>request chassis scg offline slotnumberAttach an electrostatic discharge (ESD) wrist strap to your bare wrist, and connect the wrist strap to one of the ESD points on the chassis. Press the online/offline button on the SCG faceplate and hold it down until the LED goes out (about 5 seconds).
- Loosen the captive screws on the edges of the SCG faceplate.
- Grasp the SCG by the handle on the faceplate and slide it out of the chassis.
- Place the SCG on the antistatic mat.
- Remove the replacement SCG from its electrostatic bag.
- Carefully align the sides of the SCG with the guides in the SCG slot.
- Grasp the SCG by its handle and slide it straight into the chassis until it contacts the midplane.
- Tighten the captive screws on the corners of the SCG faceplate.
- Bring the SCG online by doing one of the following:
user@host> request chassis scg online slotnumberPress the online/offline button until the green ONLINELED lights.
- Verify that the SCG is online by using the following CLI command:
user@host>request chassis scg online slotnumberIf the replaced SCG is online, the removed SCG has failed. Return the SCG as described in Return the Failed Component.