Monitoring Redundant SCGs

You monitor and maintain redundant SONET Clock Generators (SCGs) installed in the T320 router and the T640 routing node to ensure that there is no interruption of function. SCGs provide a clock signal for SONET/SDH, and select a clock signal from any Flexible PIC Concentrator (FPC), or from the external clock inputs.

Table 117 lists the tasks you perform to monitor redundant SCGs.


Table 117: Checklist for Monitoring the Redundant SCG
Monitor SCG Tasks
Command or Action

show chassis hardware

  1. Monitor the Redundant SCG Environmental Status

show chassis environment

show chassis environment scg

  1. Display the Redundant SCG LED States at the Command Line

show chassis craft-interface

  1. View the Redundant SCG LEDs

Remove the rear component cover and look on the SCG faceplate at the back of the T320 router or T640 routing node chassis.

  1. Display the SCG Master and Standby from the Craft Interface Output

show chassis craft-interface

  1. View the SCG LEDs

Remove the rear component cover and look on the SCG faceplate at the rear of the T320 router or T640 routing node chassis.

  1. Take the SCG offline.

request chassis scg offline slot number

  1. Replace the SCG with one that you know works.
  2. Bring the SCG online.

request chassis scg offline slot number

  1. Verify the SCG status.

request chassis scg offline slot number

See Return the Failed Component, or follow the procedure in the M40e or M160 router hardware guide.