[Contents] [Prev] [Next] [Index] [Report an Error]


Monitoring Redundant MCSs

You monitor and maintain redundant Miscellaneous Control Subsystems (MCSs) installed in the M40e or M160 router to ensure that there is no interruption of functions such as the following:

For more information about monitoring a single MCS, see Monitoring the MCS.

Table 121 provides a checklist of tasks you perform to monitor redundant MCSs.


Table 121: Checklist for Monitoring Redundant MCSs
Monitor Redundant MCS Tasks
Command or Action

show chassis hardware

  1. Check the Redundant MCS Environmental Status

show chassis environment mcs

  1. Check the Redundant MCS Status from the Craft Interface

show chassis craft-interface

  1. Check the Redundant MCS LED Status

Check the LEDs on the MCS faceplate.

  1. Check the Redundant MCS Environmental Status

show chassis environment mcs

  1. Check the Redundant MCS Status from the Craft Interface

show chassis craft-interface

  1. Check the Redundant MCS LED Status

Check the LEDs on the MCS faceplate.

Manually take the MCS offline by pressing the offline button on the component faceplate.

  1. Take the host module offline.
  2. Take the MCS offline.
  3. Remove the MCS and replace it with one that you know works.

See Return the Failed Component, or follow the procedure in the M40e or M160 router hardware guide.



[Contents] [Prev] [Next] [Index] [Report an Error]