Step 1: Check the Redundant Control Board Environmental Status
Action
To check the redundant Control Board environmental status, use the following CLI command:
user@host>show chassis environment cbSample Output
t640@host>show chassis environment cbCB 0 status:State Online MasterTemperature 29 degrees C / 84 degrees FPower:1.8 V 1805 mV2.5 V 2501 mV3.3 V 3293 mV4.6 V 4725 mV5.0 V 5032 mV12.0 V 11975 mV3.3 V bias 3286 mV8.0 V bias 7589 mVGBUS Revision 40FPGA Revision 7CB 1 status:State Online StandbyTemperature 32 degrees C / 89 degrees FPower:1.8 V 1802 mV2.5 V 2482 mV3.3 V 3289 mV4.6 V 4720 mV5.0 V 5001 mV12.0 V 11946 mV3.3 V bias 3274 mV8.0 V bias 7562 mVGBUS Revision 40FPGA Revision 7What It Means
The command output displays which Control Board is master and standby. Additionally, the command output displays the Control Board state, redundancy status, temperature, power source, and circuitry revision level for each Control Board installed in the router chassis.
CB1is shown in standby mode, and is the redundant Control Board.Alternative Action
To display the environmental status of a particular Control Board, use the following JUNOS CLI operational mode command:
t640@host>show chassis environment cb slot