[Contents] [Prev] [Next] [Index] [Report an Error]


Step 3: Display PCG Error Messages in the Chassis Daemon Log File

Action

To display the PCG error messages in the chassis daemon (chassisd) log file, use the following CLI command:

user@host> show log chassisd

Sample Output

user@host> show log chassisd
Jun 11 20:31:17 FPC 7 - Disable Power [addr 0x17 cmd 0x10]
Jun 11 20:31:17 CMB readback FPC 7 [0xf7, 0xf2] -> 0x26
Jun 11 20:31:17 power disable verified, FPC 7
Jun 11 20:31:17 CHASSISD_IFDEV_DETACH: ifdev_detach(7)
Jun 11 20:31:17 ifd so-7/0/0 marked as gone
Jun 11 20:31:19 PCG 0 set alarm 0x3
Jun 11 20:31:19 alarm op fru 1 op 1 reason 3
Jun 11 20:31:19 send: yellow alarm set, class 100 obj 110 reason 3
Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Disable Power [0x10]
Jun 11 20:31:19 PCG 0 - Disable Power [addr 0x2 cmd 0x10]
Jun 11 20:31:19 CMB readback PCG 0 [0xe2, 0xf2] -> 0x6
Jun 11 20:31:19 power disable verified, PCG 0
Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Blue LED Off [0x16]
Jun 11 20:31:19 PCG 0 - Blue LED Off
Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Green LED Off [0x1a]
Jun 11 20:31:19 PCG 0 - Green LED Off
Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Amber LED Off [0x18]
Jun 11 20:31:19 PCG 0 - Amber LED Off
Jun 11 20:31:19 mcs_intr_handler fpm_mcsfd 10
Jun 11 20:31:19 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x0
Jun 11 20:31:19 bp_handle_button_intr button status 0x0
Jun 11 20:31:21 reading FPC 0 initial state
Jun 11 20:31:21 CMB readback FPC 0 [0xf0, 0xff] -> 0xc
Jun 11 20:31:21 reading FPC 0 ideeprom
Jun 11 20:31:21 reading FPC 1 initial state
Jun 11 20:31:21 CMB readback FPC 1 [0xf1, 0xff] -> 0xc
Jun 11 20:31:21 reading FPC 1 ideeprom
Jun 11 20:31:21 reading FPC 2 initial state
Jun 11 20:31:21 CMB readback FPC 2 [0xf2, 0xff] -> 0xc
Jun 11 20:31:21 reading FPC 2 ideeprom
Jun 11 20:31:21 reading FPC 6 initial state
Jun 11 20:31:21 CMB readback FPC 6 [0xf6, 0xff] -> 0xc
Jun 11 20:31:21 reading FPC 6 ideeprom
Jun 11 20:31:21 reading FPC 7 initial state
Jun 11 20:31:21 CMB readback FPC 7 [0xf7, 0xff] -> 0xc
Jun 11 20:31:21 reading FPC 7 ideeprom
Jun 11 20:31:21 gen_sfm_wait_mask 0x0
Jun 11 20:31:21 ...power sequencer started...

What It Means

The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.