Checking the Control Board Status

This section provides a brief description of monitoring the Control Board as part of the host subsystem on T320 routers and T640 routing nodes. For more information about monitoring the Control Board, see Monitoring the Control Board.

Action

To monitor the Control Board environmental status, use the following CLI command:

user@host> show chassis environment cb

Sample Output

user@host> show chassis environment cb
CB 0 status:
  State                           Online Master
  Temperature                  32 degrees C / 89 degrees F
  Power:
    1.8 V                    1807 mV
    2.5 V                    2473 mV
    3.3 V                    3312 mV
    4.6 V                    4793 mV
    5.0 V                    5008 mV
    12.0 V                  11677 mV
    3.3 V bias               3294 mV
    8.0 V bias               7272 mV
  BUS Revision                 16
  FPGA Revision                45
CB 1 status:
  State                           Online Standby
  Temperature                  31 degrees C / 87 degrees F
  Power:
    1.8 V                    1809 mV
    2.5 V                    2448 mV
    3.3 V                    3305 mV
    4.6 V                    4765 mV
    5.0 V                    4989 mV
    12.0 V                  11633 mV
    3.3 V bias               3284 mV
    8.0 V bias               7301 mV
  BUS Revision                 16
  FPGA Revision                45

What It Means

The command output displays environmental information about both Control Boards installed in the router. It displays the Control Board slot, operating status, temperature of air flowing past the Control Board, power supply, and circuitry and field programmable gate array (FPGA) revision information.

The Control Board status can be Present, Online, Offline, or Empty. The command also indicates whether the Control Board is master.