Step 3: Check FPC Status and Temperature

Action

(M40e, M160, M320, and T320 routers and T640 routing node only) To display the FPC status and temperature for a particular FPC slot, use the following CLI command:

user@host> show chassis environment fpc fpc-slot 

user@m160> show chassis environment fpc 0
FPC 0 status:
  State                           Online
  Temperature                  39 degrees C / 102 degrees F
  Power:
    1.5 V                    1496 mV
    2.5 V                    2485 mV
    3.3 V                    3306 mV
    5.0 V                    4991 mV
    5.0 V bias               4993 mV
    8.0 V bias               8251 mV
  CMB Revision                 12

What It Means

The command output displays the status of the FPC in slot 0, including the state, temperature, voltage levels on the FPC, and the revision level of the chassis management bus slave. The state can be Unknown, Empty, Present, Ready, Announce online, Online, Offline, or Diagnostics. An Offline state indicates an FPC error condition.