[Contents] [Prev] [Next] [Index] [Report an Error]


Step 2: Check the FPC Installation

Action

To check the FPC installation and verify an FPC failure, follow these steps:

  1. Make sure that the FPC is seated in its slot. Use a screwdriver to check that the screws at the top and bottom of the card carrier are tight.
  2. Try to bring the FPC online. Press the online button on the craft interface or FPM for a few seconds. If the FPC does not come online, it has probably failed.
  3. If the FPC comes online, check the FPC detailed status with the following CLI command:
  4. user@host> show chassis fpc detail fpc-slot
    

Alternative Action

For the M40e, M160, M320 and T320 routers and T640 routing node, to bring the FPC online, use the request chassis fpc slot-number online command.


[Contents] [Prev] [Next] [Index] [Report an Error]