Monitoring FPCs

You monitor and maintain Flexible PIC Concentrators (FPCs) to connect Physical Interface Cards (PICs) to the rest of the router so that incoming packets are forwarded across the midplane to the appropriate destination ports. (See Table 44.)


Table 44: Checklist for Monitoring FPCs
Monitor FPC Tasks
Command or Action
  1. Check FPC Status and Utilization

show chassis fpc

  1. Check FPC Status and Uptime

show chassis fpc detail fpc-slot

  1. (M40e, M160, M320, and T320 routers and T640 routing node only) Check FPC Status and Temperature

show chassis environment fpc fpc-slot

  1. Check the FPC LED States

show chassis craft-interface

Or, physically check the FPC LEDs on the Front Panel Module (FPM).

  1. Display the Current FPC Alarms

show chassis alarms

  1. Display FPC Error Messages in the System Log File

show log messages | match "fpc| kernel | tnp"

  1. Display FPC Error Messages in the Chassis Daemon Log File

show log chassisd | match fpc

  1. Document Events Prior to the FPC Failure

Document a software upgrade, hardware upgrade, or reset.

  1. Check the FPC Installation

Check that the FPC is seated in the slot.

Try to bring the FPC online.

  1. Check the FPC Fuses

The fuses for the and FPCs are located in the rear of the midplane behind the power supply in slot PEM0.

  1. Take the FPC Offline

Press the offline button for approximately 3 seconds.

  1. Perform an FPC Swap Test

Replace the FPC with one that you know works.

  1. Display the FPC Software Version Information

show version brief

  1. Display the FPC Hardware Information

show chassis hardware

  1. Locate the FPC Serial Number ID Label
  • M20 Internet router—With the FPC in horizontal position, look on the top back right of the FPC.
  • M40 Internet router—With the FPC in vertical position, look on the back left side of the FPC.
  • M40e and M160 routers—With the FPC in vertical position, look on the center right side of the FPC.
  • For M320 routers—On an FPC3, the serial number ID label is located on the center of the right side. On an FPC2, the serial number label is located on the top PIC slot.
  • For T320 routers—On an FPC3, the serial number ID label is located on the center of the right side. On an FPC1 and FPC2, the serial number ID label is located near the top PIC slot.
  • For T640 routing nodes—On an FPC3, the serial number label is located on the center of the right side. On an FPC2, the serial number label is located near the top PIC slot.

See Return the Failed Component. Follow the procedure in the appropriate router hardware guide.