[Contents] [Prev] [Next] [Index] [Report an Error]


Step 2: Display FIC Status at the Command Line

Action

To display the FIC status, use the following CLI command:

user@host> show chassis pic pic-slot 3 fpc-slot 1

Sample Output

user@host> show chassis pic pic-slot 3 fpc-slot 1  
PIC fpc slot 1 pic slot 3 information:
  Type                             1x G/E, 1000 BASE
  ASIC type                        QGE FPGA
  State                            Online    
  PIC version                  1.4
  Uptime                        12 hours, 11 minutes, 39 seconds

PIC Port Information:
  Port        Cable             SFP                SFP Vendor
  Number      Type              Vendor Name        Part Number
  0           UNKNOWN CABLE 

What It Means

Since the FIC is located in FPC 1 slot 3, you must specify its location with the show chassis pic CLI command. The command output displays the FIC information, such as the FIC type, ASIC type, operating status, PIC version, and the amount of time the FIC has been online. The command output also displays port cable information.