Step 2: Display FIC Status at the Command Line
Action
To display the FIC status, use the following CLI command:
user@host> show chassis pic pic-slot 3 fpc-slot 1Sample Output
user@host> show chassis pic pic-slot 3 fpc-slot 1PIC fpc slot 1 pic slot 3 information:Type 1x G/E, 1000 BASEASIC type QGE FPGAState OnlinePIC version 1.4Uptime 12 hours, 11 minutes, 39 secondsPIC Port Information:Port Cable SFP SFP VendorNumber Type Vendor Name Part Number0 UNKNOWN CABLEWhat It Means
Since the FIC is located in FPC 1 slot 3, you must specify its location with the
show chassis picCLI command. The command output displays the FIC information, such as the FIC type, ASIC type, operating status, PIC version, and the amount of time the FIC has been online. The command output also displays port cable information.