[Contents] [Prev] [Next] [Index] [Report an Error]


M320 Router Cooling System

The M320 cooling system consists of the following components (see Figure 115):


Figure 115: M320 Router Cooling System and Airflow

The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at lower than full speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is automatically adjusted to keep the temperature within the acceptable range. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down some or all of the hardware components.

Figure 116 shows the M320 router airflow.


Figure 116: M320 Router Cooling System and Airflow

[Contents] [Prev] [Next] [Index] [Report an Error]