Monitoring the Cooling System

You monitor and maintain the cooling system to keep an acceptable operating temperature for the router chassis and its components. (See Table 67.)


Table 67: Checklist for Monitoring the Cooling System
Monitor Cooling System Tasks
Command or Action

show chassis environment

  1. Check the Alarm Indicators on the Craft Interface

show chassis craft-interface

Check the router craft interface.

  1. Display Current Cooling System Alarms

show chassis alarms

  1. Display Cooling System Error Messages in the System Log File

show log messages | match fan

Inspect the air filter. If dirty, clean it; if damaged, replace it.

Perform a swap test on the fan. If defective, replace it without powering down the router.

Feel the impeller air exhaust. If no airflow, replace without powering down the router.

Follow the procedure in the appropriate router hardware guide.