[Contents] [Prev] [Next] [Index] [Report an Error]


Monitoring the CIP

You monitor the Connector Interface Panel (CIP) to ensure management connection to the M40e, M160, M320, T320, and T640 routing node Routing Engines, Building Integrated Timing Source (BITS) interfaces for the Miscellaneous Control Subsystem (MCS), and alarm relay contacts. (See Table 91.)


Table 91: Checklist for Monitoring the CIP
Tasks for Monitoring the CIP
Command or Action

show chassis environment

  1. Display Current CIP Alarms

show chassis alarms

  1. Display CIP Error Messages in the System Log File

show log messages

  1. Display CIP Error Messages in the Chassis Daemon Log File

show log chassisd

  1. Check the CIP Connection

Check the connector screws on the CIP faceplate.

  1. Check the Ethernet Port Functionality
  1. Connect to the Ethernet port.
  2. Check the LINK LED.
  3. Run the JUNOS software CLI.
  1. Performing a CIP Swap Test
  1. Power down the router.
  2. Remove the CIP.
  3. Replace the CIP with one that you know works.
  4. Power on the router.
  1. Display CIP Hardware Information

show chassis hardware

  1. Locating the CIP Serial Number ID Label

Look on the top of the left side of the CIP.

Power down the router. To replace and return a CIP, follow the instructions in the M40e or M160 router hardware guide.