[Contents][Prev][Next][Index][Report an Error]
thresholds
Syntax
- thresholds thresholds;
Hierarchy Level
- [edit services rpm probe owner test test-name]
Release Information
Statement introduced before JUNOS Release
7.4.
Description
Specify thresholds used for the probes. A system
log message is generated when the configured threshold is exceeded.
Likewise, a Simple Network Management Protocol (SNMP) trap (if configured)
is generated when a threshold is exceeded.
Options
-
thresholds—Specify
one or more threshold measurements. The following options are supported:
-
egress-time—Measures maximum source-to-destination
time per probe.
-
ingress-time—Measures maximum destination-to-source
time per probe.
-
jitter-egress—Measures maximum source-to-destination
jitter per test.
-
jitter-ingress—Measures maximum destination-to-
source jitter per test.
-
jitter-rtt—Measures maximum jitter per
test, from 0 through 60,000,000 microseconds.
-
rtt—Measures maximum round-trip time per
probe, in microseconds.
-
std-dev-egress—Measures maximum source-to-destination
standard deviation per test.
-
std-dev-ingress—Measures maximum destination-to-source
standard deviation per test.
-
std-dev-rtt—Measures maximum standard deviation
per test, in microseconds.
-
successive-loss—Measures successive probe
loss count, indicating probe failure.
-
total-loss—Measures total probe loss count
indicating test failure, from 0 through 15.
Usage Guidelines
See Configuring the Probe.
Required Privilege Level
interface—To view this statement
in the configuration.
interface-control—To add this statement to
the configuration.
[Contents][Prev][Next][Index][Report an Error]