- pem {
- minimum number;
- }
- [edit chassis]
Statement introduced in JUNOS Release 7.4.
Configure the minimum number of PEMs on an M320 router. With this configuration, PEM absent alarms are generated only if the PEM count falls below the minimum specified.
number—Minimum number of PEMs on the router.
See Configuring an Entry-Level M320 Router.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.