- alarm {
-
-
interface-type {
-
alarm-name (red | yellow | ignore);
- }
- }
- [edit chassis]
Statement introduced before JUNOS Release 7.4.
Configure the chassis alarms and whether they trigger a red or yellow alarm, or whether they are ignored. Red alarm conditions light the RED ALARM LED on the router’s craft interface and trigger an audible alarm if one is connected to the contact on the craft interface. Yellow alarm conditions light the YELLOW ALARM LED on the router’s craft interface and trigger an audible alarm if one is connected to the craft interface.
To configure more than one alarm, include multiple alarm-name lines.
alarm-name—Alarm condition. For a list of conditions, see Table 40.
ignore—The specified alarm condition does not set off any alarm.
interface-type—Type of interface on which you are configuring the alarm. It can be one of the following: atm, ethernet, sonet, or t3.
red—The specified alarm condition sets off a red alarm.
yellow—The specified alarm condition sets off a yellow alarm.
See Chassis Conditions That Trigger Alarms.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.