[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
traps
Syntax
- traps traps;
Hierarchy Level
- [edit services rpm probe owner test test-name]
Release Information
Statement introduced before JUNOS Release
7.4.
Description
Set the trap bit to generate traps for probes.
Traps are sent if the configured threshold is met or exceeded.
Options
-
traps—Specify one or more traps. The following options are supported:
-
egress-jitter-exceeded—Generates traps
when the jitter in egress time threshold is met or exceeded.
-
egress-std-dev-exceeded—Generates traps
when the egress time standard deviation threshold is met or exceeded.
-
egress-time-exceeded—Generates traps when
the maximum egress time threshold is met or exceeded.
-
ingress-jitter-exceeded—Generates traps
when the jitter in ingress time threshold is met or exceeded.
-
ingress-std-dev-exceeded—Generates traps
when the ingress time standard deviation threshold is met or exceeded.
-
ingress-time-exceeded—Generates traps when
the maximum ingress time threshold is met or exceeded.
-
jitter-exceeded—Generates traps when the
jitter in round-trip time threshold is met or exceeded.
-
probe-failure—Generates traps for successive
probe loss thresholds crossed.
-
rtt-exceeded—Generates traps when the maximum
round-trip time threshold is met or exceeded.
-
std-dev-exceeded—Generates traps when the
round-trip time standard deviation threshold is met or exceeded.
-
test-completion—Generates traps when a
test is completed.
-
test-failure—Generates traps when the total
probe loss threshold is met or exceeded.
Usage Guidelines
See Configuring the Probe.
Required Privilege Level
interface—To view this statement
in the configuration.
interface-control—To add this statement to
the configuration.
[Contents]
[Prev]
[Next]
[Index]