See the following sections:
- sustained-data-rate default bytes-per-second;
- [edit services pgcp gateway gateway-name h248-properties traffic-management]
Statement introduced in JUNOS Release 9.2.
Configure the sustained data rate for streams of any protocol, including RTP.
The PG uses the default value of 10,000 bytes per second if the Policy command in H.248 messages in ON and both of the following apply:
bytes-per-second—Sustained data rate.
See Configuring Default Values for H.248 Properties.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
JUNOS Multiplay Solutions Guide
- sustained-data-rate {
-
- rtcp {
- fixed-value bytes-per-second;
- percentage percentage;
- }
- }
- [edit services pgcp gateway gateway-name h248-properties traffic-management]
Statement introduced in JUNOS Release 9.2.
Configure the sustained data rate for RTP/RTCP gate streams. You can configure this rate as a fixed value or as a percentage of RTP's sustained data rate.
The PG uses the default value of 5 percent of the RTP gate's rate if the Policy command in H.248 messages in ON and both of the following apply:
fixed-value—Value entered is a fixed number of bytes per second.
bytes-per-second—Sustained data rate.
percentage—Value entered is a percentage of the RTP gate's rate.
percentage—Sustained data rate as a percentage of the RTP gate's rate.
See Configuring Default Values for H.248 Properties.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
JUNOS Multiplay Solutions Guide