To configure the association between AS or MultiServices PICs hosting link services IQ interfaces and the SONET interfaces, include the lsq-failure-options statement at the [edit interfaces] hierarchy level:
- lsq-fpc/pic/port {
-
-
lsq-failure-options {
-
no-termination-request;
- [ trigger-link-failure interface-name ];
- }
- }
For example, consider the following network scenario:
Configure SONET APS, with oc3-0/2/0 as the working circuit and oc3-2/2/0 as the protect circuit. Configure the following to extend failure to the LSQ PICs:
- interfaces lsq-1/1/0 {
-
-
lsq-failure-options {
-
trigger-link-failure oc3-0/2/0;
- }
- }
![]() |
Note: You must configure the lsq-failure-options statement on the primary router only. The configuration is not supported on the backup router. |
To inhibit the router from sending PPP termination-request messages to the remote host if the Link Services IQ PIC fails, include the no-termination-request statement at the [edit interfaces lsq-fpc/pic/port lsq-failure-options] hierarchy level:
-
no-termination-request;
This functionality has been extended to the link PICs as well. To inhibit the router from sending PPP termination-request messages to the remote host if a link PIC fails, include the no-termination-request statement at the [edit interfaces interface-name ppp-options] hierarchy level.
The no-termination-request statement is supported only with MLPPP and SONET APS configurations and works with PPP, PPP over Frame Relay, and MLPPP interfaces only. The supported PIC types are as follows: