frame-error

Syntax

frame-error count;

Hierarchy Level

[edit protocols oam ethernet link-fault-management action-profile event link-event-rate],
[edit protocols oam link-fault-management interface interface-name event-thresholds]

Release Information

Statement introduced in JUNOS Release 8.4.

Description

Threshold for sending frame error events or taking the action specified in the action profile.

A frame error is any frame error on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value within the window. The default window is 1 second and is not configurable.

Options

count—Threshold count for frame error events.

Range: 1 through 100

Usage Guidelines

See Configuring Threshold Values for Local Fault Events on an Interface and Configuring Threshold Values for Fault Events in an Action Profile.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.