jnxCtlOwnerIndex
|
jnxPingCtlEntry 1
|
The first index. It is identical to the pingCtlOwnerIndex of the corresponding pingCtlEntry in the pingCtlTable.
|
|
jnxPingCtlTestName
|
jnxPingCtlEntry 2
|
The other index and is identical to the pingCtlTestName of the corresponding pingCtlEntry in the pingCtlTable.
|
|
jnxPingCtlIfName
|
jnxPingCtlEntry 3
|
Specifies the name of the outgoing interface for ping probes.
This is the name-based complement to pingCtlIfIndex. A zero-length
string value for this object means that this option is not enabled.
The following values can be set simultaneously, but only one value
is used. The precedence order is as follows:
-
pingCtlIfIndex (see pingCtlTable in
the Ping MIB)
-
jnxPingCtlIfName
-
jnxPingCtlRoutingInstanceName
|
|
jnxPingCtlRoutingInstanceName
|
jnxPingCtlEntry 6
|
Specifies the name of the routing instance used when directing
outgoing ping packets. The instance name specified must be configured
at the [edit routing-instances] hierarchy level of the JUNOS
configuration. The instance-type must be vrf.
|
|
jnxPingCtlRttThreshold
|
jnxPingCtlEntry 7
|
The maximum round-trip time allowed. If this threshold is crossed
by any probe, a jnxPingRttThresholdExceeded trap will be
sent.
|
|
jnxPingCtlRttStdDevThreshold
|
jnxPingCtlEntry 8
|
The maximum round-trip time standard deviation allowed over
the course of any test. If the calculated standard deviation of the
round-trip time at the end of any test exceeds this threshold, a jnxPingRttStdDevThresholdExceeded trap will be sent.
|
|
jnxPingCtlRttJitterThreshold
|
jnxPingCtlEntry 9
|
The maximum allowed jitter in the round-trip time over the course
of any test. Jitter is the difference between the maximum and minimum
round-trip times measured over the course of a single test (jnxPingResultsMaxRttUs minus jnxPingResultsMinRttUs). If the measured jitter exceeds
this threshold, a jnxPingRttJitterThresholdExceeded trap
is sent.
|
|
jnxPingCtlEgressTimeThreshold
|
jnxPingCtlEntry 10
|
Maximum egress trip time allowed. If this threshold is crossed
by any probe, a jnxPingEgressThresholdExceeded trap will
be sent. This applies only if the probe type (pingCtlType) provides one-way delay measurements. Currently jnxPingIcmpTimeStamp is the only supported probe type with this property.
|
|
jnxPingCtlEgressStdDevThreshold
|
jnxPingCtlEntry 11
|
The maximum egress trip time standard deviation allowed over
the course of any test. If the calculated standard deviation of the
egress trip time at the end of any test exceeds this threshold, a jnxPingEgressStdDevThresholdExceeded trap will be sent. This
applies only if the probe type (pingCtlType) provides one-way delay
measurements. The jnxPingIcmpTimeStamp is the only supported
probe type with this property.
|
|
jnxPingCtlEgressJitterThreshold
|
jnxPingCtlEntry 12
|
The maximum allowed jitter in the egress trip time over the
course of any test. Jitter is defined as the difference between the
maximum and minimum egress trip times measured over the course of
a single test (jnxPingResultsMaxSrcDstt minus jnxPingResultsMinSrcDstt). If the measured jitter exceeds this threshold, a jnxPingEgressJitterThresholdExceeded trap will be sent. This applies only if the probe type (pingCtlType) provides one-way delay measurements. The jnxPingIcmpTimeStamp is the only supported probe type with this property.
|
|
jnxPingCtlIngressTimeThreshold
|
jnxPingCtlEntry 13
|
The maximum ingress trip time allowed. If this threshold is
crossed by any probe, a jnxPingIngressThresholdExceeded trap
will be sent. This applies only if the probe type (pingCtlType) provides one-way delay measurements. The jnxPingIcmpTimeStamp is the only supported probe type with this property.
|
|
jnxPingCtlIngressStddevThreshold
|
jnxPingCtlEntry 14
|
The maximum ingress trip time standard deviation allowed over
the course of any test. If the calculated standard deviation of the
ingress trip time at the end of any test exceeds this threshold, a jnxPingIngressStddevThresholdExceeded trap will be sent. This
applies only if the probe type (pingCtlType) provides one-way
delay measurements. Currently jnxPingIcmpTimeStamp is the
only supported probe type with this property.
|
|
jnxPingCtlIngressJitterThreshold
|
jnxPingCtlEntry 15
|
The maximum allowed jitter in the ingress trip time over the
course of any test. Jitter is defined as the difference between the
maximum and minimum ingress trip times measured over the course of
a single test (jnxPingResultsMaxDstSrct minus jnxPingResultsMinDstSrct). If the measured jitter exceeds this threshold, a jnxPingIngressJitterThresholdExceeded trap will be sent. This applies only if the probe type (pingCtlType) provides one-way delay measurements. The jnxPingIcmpTimeStamp is the only supported probe type with this property.
|
|
jnxPingCtlTrapGeneration
|
jnxPingCtlEntry 16
|
The value of this object determines when and if to generate
a notification for this entry.
rttThreshold(0)—Generate a jnxPingRttThresholdExceeded notification when the configured RTT threshold is exceeded.
rttStdDevThreshold(1)—Generate a jnxPingRttStdDevThresholdExceeded notification when the configured RTT standard deviation threshold
is exceeded.
rttJitterThreshold(2)—Generate a jnxPingRttJitterThresholdExceeded notification when the configured RTT jitter threshold is exceeded.
egressThreshold(3)—Generate a jnxPingEgressThresholdExceeded notification when the configured egress threshold is exceeded. This
applies only if the probe type supports one-way measurements.
|
| | |
egressStdDevThreshold(4)—Generate a jnxPingEgressStdDevThresholdExceeded notification when the configured egress standard deviation threshold
is exceeded. This applies only if the probe type supports one-way
measurements.
egressJitterThreshold(5)—Generate a jnxPingEgressJitterThresholdExceeded notification when the configured egress jitter threshold is exceeded.
This applies only if the probe type supports one-way measurements.
ingressThreshold(6)—Generate a jnxPingIngressThresholdExceeded notification when the configured ingress threshold is exceeded.
This applies only if the probe type supports one-way measurements.
ingressStdDevThreshold(7)—Generate a jnxPingIngressStdDevThresholdExceeded notification when the configured ingress standard deviation threshold
is exceeded. This applies only if the probe type supports one way
measurements.
ingressJitterThreshold(8)—Generate a jnxPingIngressJitterThresholdExceeded notification when the configured ingress jitter threshold is exceeded.
This applies only if the probe type supports one-way measurements.
The value of this object defaults to zero, indicating that none of
the above options have been selected.
|