- falling-threshold integer;
- [edit snmp rmon alarm index]
Statement introduced before JUNOS Release 7.4.
The lower threshold for the sampled variable. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval is greater than this threshold, a single event is generated. A single event is also generated if the first sample after this entry becomes valid is less than or equal to this threshold, and the associated startup-alarm is equal to falling-alarm or rising-or-falling-alarm. After a falling event is generated, another falling event cannot be generated until the sampled value rises above this threshold and reaches the rising-threshold.
integer—The lower threshold for the alarm entry.
See Configuring the Falling Threshold or Rising Threshold.
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.