feb

feb (Creating a Redundancy Group)

Syntax

feb {
redundancy-group group-name {
description description;
feb slot-number (backup | primary);
no-auto-failoverr;
}
}

Hierarchy Level

[edit chassis redundancy]

Release Information

Statement introduced in JUNOS Release 8.2.

Description

On M120 routers only, configure a Forwarding Engine Board (FEB) redundancy group.

Options

The remaining statements are described separately.

Usage Guidelines

See Configuring FEB Redundancy on the M120 Router.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

feb (Assigning a FEB to a Redundancy Group)

Syntax

feb slot-number (backup | primary);

Hierarchy Level

[edit chassis redundancy feb redundancy-group group-name]

Release Information

Statement introduced in JUNOS Release 8.2.

Description

On M120 routers only, configure a Forwarding Engine Board (FEB) as part of a FEB redundancy group.

Options

slot-number—Slot number of the FEB. The range of values is from 0 to 5.

backup—(Optional) For each redundancy group, you must configure exactly one backup FEB.

primary—(Optional) For each redundancy group, you can optionally configure one primary FEB.

Usage Guidelines

See Configuring FEB Redundancy on the M120 Router.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.