show chassis temperature-thresholds
Syntax
- show chassis temperature-thresholds
Release Information
Command introduced in JUNOS Release 8.0.
Description
Display chassis temperature threshold settings,
in degrees Celsius.
Options
This command has no options.
Required Privilege Level
view
List of Sample Output
show chassis temperature-thresholds
show chassis temperature-thresholds
Output Fields
Table 86 lists the output fields for the show chassis temperature-thresholds command. Output fields are listed in the approximate order in which
they appear.
Table 86: show chassis
temperature-thresholds Output Fields
|
Field name
|
Field Description
|
|
Item
|
Chassis component. If per FRU per slot thresholds
are configured, the components about which information is displayed
include the chassis, the Routing Engines, FPCs, and FEBs. If per FRU
per slot thresholds are not configured, the components about which
information is displayed include the chassis and the Routing Engines.
|
|
Fan speed
|
The temperature threshold settings, in degrees
Celsius, for the fans to operate at normal and high speeds.
-
Normal—The fans operate at normal speed
if the component is at or below this temperature and all the fans
are present and functioning normally.
-
High—The fans operate at high speed if
the component has exceeded this temperature or a fan has failed or
is missing.
An alarm is not triggered until the temperature exceeds
the threshold settings for a yellow alarm or a red alarm.
|
|
Yellow alarm
|
The temperature threshold settings, in degrees
Celsius, that trigger a yellow alarm.
-
Normal—The component has exceeded this
temperature and the fans have been turned on to full speed.
-
Bad fan—The component has exceeded this
temperature and one or more fans have failed or are missing.
|
|
Red alarm
|
The temperature threshold settings, in degrees
Celsius, that trigger a red alarm.
-
Normal—The component has exceeded this
temperature and the fans have been turned on to full speed.
-
High—The component has exceeded this temperature
and one or more fans have failed or are missing.
|
show chassis temperature-thresholds
user@host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 70 80 95 95 110 110
Routing Engine 1 70 80 95 95 110 110
FPC 0 55 60 75 65 90 80
FPC 1 55 60 75 65 90 80
FPC 2 48 54 70 60 80 70
FPC 3 48 54 70 60 80 70
FPC 4 48 54 70 60 80 70
FPC 5 48 54 70 60 80 70
FEB 0 48 54 70 60 80 70
FEB 1 48 54 70 60 80 70
FEB 2 48 54 70 60 80 70
FEB 3 48 54 70 60 80 70
FEB 4 48 54 70 60 80 70
FEB 5 48 54 70 60 80 70
show chassis temperature-thresholds
user@host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 70 80 95 95 110 110
Routing Engine 1 48 54 85 85 100 100