[Contents] [Prev] [Next] [Index] [Report an Error]

show chassis pic

Syntax

show chassis pic fpc-slot slot-number pic-slot slot-number

Syntax (Routing Matrix)

show chassis pic fpc-slot slot-number pic-slot slot-number
<lcc number>

Release Information

Command introduced before JUNOS Release 7.4.

Description

Display status information about the Physical Interface Card (PIC) installed in the specified Flexible PIC Concentrator (FPC) and PIC slot.

Options

fpc-slot slot-numberDisplay information about the PIC in this particular FPC slot:

lcc number(Routing matrix only) (Optional) Display PIC information for a specified T640 routing node (or line-card chassis) that is connected to a TX Matrix platform. Replace number with a value from 0 through 3.

pic-slot slot-numberDisplay information about the PIC in this particular PIC slot. Replace slot-number with a value from 0 through 3.

Required Privilege Level

view

Related Topics

request chassis pic

List of Sample Output

show chassis pic fpc-slot pic-slot
show chassis pic fpc-slot pic-slot (PIC Offline)
show chassis pic fpc-slot pic-slot (FPC Offline)
show chassis pic fpc-slot pic-slot (FPC Not Present)
show chassis pic fpc-slot pic-slot (PIC Not Present)
show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)
show chassis pic fpc-slot pic-slot (MX960 Router Bidirectional Optics)
show chassis pic fpc-slot pic-slot lcc (Routing Matrix)
show chassis pic fpc-slot pic-slot (Next-generation SONET/SDH SFP)
show chassis pic fpc-slot pic-slot (12-port T1/E1)
show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)
show chassis pic fpc-slot pic-slot (OTN)

Output Fields

Table 74 lists the output fields for the show chassis pic command. Output fields are listed in the approximate order in which they appear.

Table 74: show chassis pic Output Fields

Field Name

Field Description

Type

PIC type.

ASIC type

Type of ASIC on the PIC.

State

Status of the PIC. State is displayed only when a PIC is in the slot: Online  or Offline.

PIC version

PIC hardware version.

Uptime

How long the PIC has been online.

Package

(MultiServices PICs only) Services package supported: Layer-2 or Layer-3.

PIC Port Information

Port-level information for the PIC.

Port Number

Port number for the PIC.

Cable Type

Type of cable connected to the port: LH, LX, or SX

PIC Port Information (MX960 Router Bidirectional Optics)

Port-level information for the PIC.

  • Port—Port number
  • Cable type—Type of small form-factor pluggable (SFP) optical transceiver installed. Uplink interfaces display -U. Down link interfaces display -D.
  • Fiber type—Type of fiber. SM is single-mode.
  • Xcvr vendor—Transceiver vendor name.
  • Xcvr vendor part number—Transceiver vendor part number.
    • BX10-10-km bidirectional optics.
    • BX40-40-km bidirectional optics.
    • SFP-LX-40-km SFP optics.
  • Wavelength—Wavelength of the transmitted signal. Uplinks are always 1310 nm. Downlinks are either 1490 nm or 1550 nm.

PIC Port Information (next-generation SONET/SDH SFP)

Port-level information for the next-generation SONET/SDH SFP PIC.

  • Port—Port number
  • Cable type—Type of small form-factor pluggable (SFP) optical transceiver installed.
  • Fiber type—Type of fiber: SM (single-mode) or MM (multimode).
  • Xcvr vendor—Transceiver vendor name.
  • Xcvr vendor part number—Transceiver vendor part number.
  • Wavelength—Wavelength of the transmitted signal. Next-generation SONET/SDH SFPs use 1310 nm.

show chassis pic fpc-slot pic-slot

user@host> show chassis pic fpc-slot 2 pic-slot 0
PIC fpc slot 2 pic slot 0 information:
  Type                             10x 1GE(LAN), 1000 BASE
  ASIC type                        H chip
  State                            Online    
  PIC version                      1.1
  Uptime                           1 day, 50 minutes, 58 seconds
PIC Port Information:
  Port        Cable 
  Number      Type
  0           GIGE 1000LX
  6           GIGE 1000LX

show chassis pic fpc-slot pic-slot (PIC Offline)

user@host> show chassis pic fpc-slot 1 pic-slot 0
PIC fpc slot 1 pic slot 0 information:
  State                            Offline   

show chassis pic fpc-slot pic-slot (FPC Offline)

user@host> show chassis pic fpc-slot 1 pic-slot 0
FPC 1 is not online

show chassis pic fpc-slot pic-slot (FPC Not Present)

user@host> show chassis pic fpc-slot 4 pic-slot 0
FPC slot 4 is empty

show chassis pic fpc-slot pic-slot (PIC Not Present)

user@host> show chassis pic fpc-slot 5 pic-slot 2
FPC 5, PIC 2 is empty

show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)

user@host> show chassis pic fpc-slot 3 pick-slot 0
PC slot 3, PIC slot 0 information:
  Type                             2x G/E IQ, 1000 BASE
  ASIC type                        IQ GE 2 VLAN-TAG FPGA
  State                            Online    
  PIC version                 1.16
  Uptime                        3 hours, 3 minutes

PIC Port Information:
  Port        Cable             Xcvr               Xcvr Vendor
  Number      Type              Vendor Name        Part Number
  0           GIGE 1000SX       FINISAR CORP.      FTRJ8519P1BNL-J3  
  1           GIGE 1000SX       FINISAR CORP.      FTRJ-8519-7D-JUN  

show chassis pic fpc-slot pic-slot (MX960 Router Bidirectional Optics)

user@host> show chassis pic fpc-slot 4 pick-slot 1
FPC slot 4, PIC slot 1 information:
  Type                             10x 1GE(LAN)
  State                            Online    
  PIC version                  0.0
  Uptime                         18 days, 5 hours, 41 minutes, 54 seconds

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  1     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  2     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  3     SFP-1000BASE-BX10-D SM  OCP                TRXBG1LXDBVM2-JW  1490 nm 
  4     SFP-1000BASE-BX10-D SM  OCP                TRXBG1LXDBVM2-JW  1490 nm 
  5     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 
  6     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 
  7     SFP-1000BASE-BX10-U SM  OCP                TRXBG1LXDBBMH-J1  1310 nm 
  8     SFP-1000BASE-BX10-U SM  OCP                TRXBG1LXDBBMH-J1  1310 nm 
  9     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 

show chassis pic fpc-slot pic-slot lcc (Routing Matrix)

user@host> show chassis pic fpc-slot 1 pic-slot 1 lcc 0
lcc0-re0:
--------------------------------------------------------------------------
PIC fpc slot 1 pic slot 1 information:
  Type                             4x OC-3 SONET, SMIR
  ASIC type                        D chip
  State                            Online    
  PIC version                  1.2
  Uptime                        5 days, 2 hours, 12 minutes, 8 seconds

show chassis pic fpc-slot pic-slot (Next-generation SONET/SDH SFP)

user@host> show chassis pic fpc-slot 4 pic-slot 0
FPC slot 4, PIC slot 0 information:
   Type                             4x OC-3 1x OC-12 SFP
   ASIC type                        D FPGA
   State                            Online
   PIC version                  1.3
   Uptime                        1 day, 50 minutes, 4 seconds
 
 PIC port information:
                           Fiber                    Xcvr vendor
   Port  Cable type        type  Xcvr vendor        part number       Wavelength
   0     OC48 short reach  SM    FINISAR CORP.      FTRJ1321P1BTL-J2  1310 nm
   1     OC3 short reach   MM    OCP                TRPA03MM3BAS-JE   1310 nm
   2     OC3 short reach   MM    OCP                TRXA03MM3BAS-JW   1310 nm
   3     OC12 inter reach  SM    FINISAR CORP.      FTLF1322P1BTR     1310 nm

show chassis pic fpc-slot pic-slot (12-port T1/E1)

user@host> show chassis pic fpc-slot 0 pic-slot 3
FPC slot 0, PIC slot 3 information:
  Type                             12x T1/E1 CE
  State                            Online    
  PIC version                  1.1
  CPU load average               1 percent
  Interrupt load average         0 percent
  Total DRAM size              128 MB
  Memory buffer utilization    100 percent
  Memory heap utilization        4 percent
  Uptime                         1 day, 22 hours, 28 minutes, 12 seconds
  Internal Clock Synchronization   Normal

show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)

user@host> show chassis pic fpc-slot 0 pic-slot 1
FPC slot 0, PIC slot 1 information:
  Type                             4x CHOC3 SONET CE SFP
  State                            Online    
  PIC version                  1.3
  CPU load average               1 percent
  Interrupt load average         0 percent
  Total DRAM size              128 MB
  Memory buffer utilization     99 percent
  Memory heap utilization        4 percent
  Uptime                         1 day, 22 hours, 55 minutes, 37 seconds
  Internal Clock Synchronization   Normal

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     OC3 short reach   MM    AVAGO              HFBR-57E0P-JU2    n/a     
  1     OC3 short reach   MM    AVAGO              HFBR-57E0P-JU2    n/a     
  3     OC3 long reach    SM    OPNEXT INC         TRF5456AVLB314    1310 nm

show chassis pic fpc-slot pic-slot (OTN)

user@host> show chassis pic fpc-slot 5 pic-slot 0
PIC fpc slot 5 pic slot 0 information:
     Type                             1x10GE(LAN),OTN
     ASIC type                        H chip
     State                            Online
     PIC version                   1.0
     Uptime                        5 minutes, 50 seconds

[Contents] [Prev] [Next] [Index] [Report an Error]