show chassis in-service-upgrade
Command introduced in JUNOS Release 9.0.
Display the status of Flexible PIC Concentrators (FPCs) and their corresponding Physical Interface Cards (PICs) after the most recent unified in-service software upgrade (ISSU). This command must be issued on the master Routing Engine.
![]() |
Note: Only Intelligent Queuing (IQ) PICs are displayed by this command output. Unified ISSU status for other PIC types is controlled internally by the FPC. |
This command has no options.
view
request system software in-service-upgrade
Table 70 lists the output fields for the show chassis in-service-upgrade command. Output fields are listed in the approximate order in which they appear.
Table 70: show chassis in-service-upgrade Output Fields
|
Field Name |
Field Description |
|---|---|
|
Item |
Flexible PIC Concentrator (FPC) slot number. |
|
Status |
FPC and corresponding PIC state: Online or Offline. |
|
Reason |
Reason for the state (if offline). |
user@host> show chassis in-service-upgrade
Item Status Reason
FPC 0 Online
FPC 1 Online
FPC 2 Online
PIC 0 Online
PIC 1 Online
FPC 3 Offline Offlined by CLI command
FPC 4 Online
PIC 1 Online
FPC 5 Online
PIC 0 Online
FPC 6 Online
PIC 3 Online
FPC 7 Online