CLI Configuration
To configure memory and session limits for application identification:
- Specify the session limit for application identification.
In the following statement you set the maximum number of sessions
that can run application identification at the same time as 600:
- user@host# set security idp sensor-configuration
application-identification max-sessions 600
- Specify the memory limit for application
identification. In the following statement you configure a maximum
of 5000 memory bytes to save packets for application identification:
- user@host# set security idp sensor-configuration
application-identification max-tcp-session-packet-memory 5000
- If you are finished configuring the router,
commit the configuration.
- From configuration mode in the CLI, enter the show security idp command to verify the configuration. For more
information, see the JUNOS Software CLI Reference.