[Contents] [Prev] [Next] [Index] [Report an Error]


Display SONET Alarms and Errors

Action

To display SONET alarms and errors, use the following JUNOS command-line interface (CLI) operational mode command:

user@host> show interfaces so-fpc/pic/port extensive

Sample Output

user@host> show interfaces so-1/1/1 extensive
[...Output truncated...]
  Active alarms  : None
  Active defects : None
  SONET PHY:            Seconds        Count  State
    PLL Lock                  0            0  OK
    PHY Light                 0            0  OK
  SONET section:
    BIP-B1                    0            0
    SEF                       0            0  OK
    LOS                       0            0  OK
    LOF                       0            0  OK
    ES-S                      0
    SES-S                     0
    SEFS-S                    0
  SONET line:
    BIP-B2                    0            0
    REI-L                     0            0
    RDI-L                     0            0  OK
    AIS-L                     0            0  OK
    BERR-SF                   0            0  OK
    BERR-SD                   0            0  OK
    ES-L                      0
    SES-L                     0
    UAS-L                     0
    ES-LFE                    0
    SES-LFE                   0
    UAS-LFE                   0
  SONET path:
    BIP-B3                    0            0
    REI-P                     0            0
    LOP-P                     0            0  OK
    AIS-P                     0            0  OK
    RDI-P                     0            0  OK
    UNEQ-P                    0            0  OK
    PLM-P                     0            0  OK
    ES-P                      0
    SES-P                     0
    UAS-P                     0
    ES-PFE                    0
    SES-PFE                   0
    UAS-PFE                   0
[...Output truncated...]

What It Means

The sample output shows where you find SONET alarms and errors. SONET alarms and errors fall into three different areas of the output: section, line, and path.

Section, line, and path errors occur over different spans of the SONET network and between different pieces of equipment. Figure 11 shows an example of a SONET network with the section, line, and path areas delimited. Figure 11 also shows the different pieces of equipment that comprise a SONET network:


Figure 11: Example of a SONET Network