Step 5: Verify the Status of the Logical Interface
Action
To verify the status of the logical interface, use the following JUNOS CLI operational mode command:
user@host> show interfaces t1-fpc/pic/port:channelSample Output 1
user@host#show interfaces t1-2/1/0:20Physical interface: t1-2/1/0:20,Enabled, Physical link is UpInterface index: 210, SNMP ifIndex: 173Link-level type: Cisco-HDLC, MTU: 1504, Clocking: Internal, Speed: T1, Loopback: Local, FCS: 16,Mode: C/Bit parity, Framing: ESFDevice flags : Present RunningInterface flags: Point-To-Point SNMP-TrapsLink flags : KeepalivesKeepalive settings: Interval 10 seconds, Up-count 1, Down-count 3Keepalive: Input: 39 (00:00:06 ago), Output: 0 (never)CoS queues : 4 supportedLast flapped : 2004-05-20 21:46:27 UTC (00:14:28 ago)Input rate : 16 bps (0 pps)Output rate : 160 bps (0 pps)DS1 alarms : NoneDS3 alarms : NoneDS1 defects : NoneDS3 defects : NoneLogical interface t1-2/1/0:20.0 (Index 74) (SNMP ifIndex 213)Flags: Point-To-PointSNMP-Traps Encapsulation: Cisco-HDLCProtocol inet, MTU: 1500Flags: NoneAddresses, Flags: Is-Preferred Is-PrimaryDestination: 10.10.1.1, Local: 10.10.1.2What It Means
The sample output shows that the channelized interface has the physical and logical links up.