T640 Routing Node Major Hardware Components

Table 12 lists the major T640 routing node components and characteristics.


Table 12: T640 Routing Node Major Hardware Components                    
Component
Quantity
Function
Redundant
Field-
Replaceable
Offline Button

Connector Interface Panel (CIP)

1

Provides ports for external management and alarm relay devices

Hot-pluggable

Control Board

1-2

Monitors and controls router components

Yes

Hot-pluggable

Yes

Cooling system

2 front fan trays,
1 rear fan tray

Cools router components

Yes

hot-removable,
hot insertable

Craft interface

1

Displays status and provides an interface for controlling router functions

Hot-removable.
hot-insertable

FPC

1-8

Connect PICs to other router components, contains Packet Forwarding Engines

Hot-removable,
hot-insertable

Yes

PIC

1-4 per FPC

Provides an interface to various network media

Hot-removable,
hot-insertable

Yes

Power supply (DC only)

2

Distributes needed voltages to router components

Yes

Hot-removable,
hot-insertable

Routing Engine

1-2

Provides routing functions and routing tables

Yes

Hot-removable,
hot-insertable

Yes

SONET Clock Generator (SCG)

1 - 2

Provides Stratum 3 SONET/SDH clockings

Yes

Hot-pluggable

Yes

SIB

5

Provides switch fabric

4 active,
1 standby

Hot-removable,
hot-insertable

Yes


Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing FRUs requires minimal router downtime. There are three types of FRUs: