Monitoring the SFMs

You monitor the Switching and Forwarding Modules (SFMs) to ensure that traffic transiting the router is handled properly. (See Table 84.)


Table 84: Checklist for Monitoring the SFMs
Monitor SFM Tasks
Command or Action
  1. Display the SFM Summary Status

show chassis sfm sfm-slot

show chassis sfm detail sfm-slot

  1. Display the SFM LED Status at the Command Line

show chassis craft-interface

  1. Check the SFM LED Status on the Faceplate

Check the SFM faceplate at the back of the M40e and M160 router chassis.

  1. Display the SFM Environmental Status

show chassis environment

show chassis environment sfm sfm-slot

  1. Display Current SFM Alarms

show chassis alarms

  1. Display SFM Error Messages in the System Log File

show log messages

  1. Display SFM Error Messages in the Chassis Daemon Log File

show log chassisd

  1. Check the SFM Connection

Check the thumbscrews on the SFM ejector locking tabs.

  1. Check the SFM Fuses

The M40e and M160 router fuses are located in a fuse box at the rear of the midplane, behind the lower rear impeller assembly.

  1. Perform an SFM Swap Test
  1. Take the SFM offline.
  2. Replace the SFM with one that you know works.
  3. Bring the SFM online.
  4. Check the SFM status.
  1. Display SFM Hardware Information

show chassis hardware

  1. Locate the SFM Serial Number ID Label

Look on the top left of the SFM component.

See Return the Failed Component, or follow the procedure in the appropriate router hardware guide.