Monitoring the SCGs

You monitor the SONET Clock Generators (SCGs) that provide a clock signal for the SONET/SDH interfaces on the T320 router and the T640 routing node. The SCGs select a clock signal from any Flexible PIC Concentrator (FPC). (See Table 75.)


Table 75: Checklist for Monitoring the SCG
Monitor SCG Tasks
Command or Action
  1. Monitor the SCG Environmental Status

show chassis environment

show chassis environment scg

  1. Display the SCG LED States at the Command Line

show chassis craft-interface

  1. Look at the SCG LEDs on the Faceplate


  1. Display the SCG Master from the Craft Interface Output

show chassis craft-interface

  1. Look at the SCG LEDs on the Faceplate


  1. Display Current SCG Alarms

show chassis alarms

  1. Display SCG Error Messages in the System Log File

show log messages

  1. Display SCG Error Messages in the Chassis Daemon Log File

show log chassisd

  1. Check the SCG Connection
  1. Make sure the SCG is properly seated in the midplane.
  2. Make sure none of the SCG pins are bent.
  3. Check the thumbscrew on the right side of the SCG.
  1. Perform an SCG Swap Test
  1. Take the SCG offline.
  2. Replace the SCG with one that you know works.
  3. Bring the SCG online.
  4. Check the SCG status.
  1. Display the SCG Hardware Information

show chassis hardware

  1. Locate the SCG Serial Number ID Label

Look on the top of the SCG, close to the midplane connector.

See Return the Failed Component, or follow the procedure in the appropriate router hardware guide.