Step 3: Check the SCB LED Status
Action
To check the SCB status, look at the LEDs on the SCB faceplate (see Figure 162).
![]()
Table 93 describes the SCB LED states.
Table 93: SCB LEDs
SCB processor is running. Normally, the blinking is faint and becomes bright only when the SCB is processing many exceptions.
If all four SCB LEDs are on, but dimly lit, the SCB is probably not seated properly. Tighten the captive screws at the top and bottom of the SCB card carrier.
If the green
RUNLED on the SCB is not blinking, the SCB processor is not functioning normally. The SCB might not be connected properly to the backplane. Tighten the screws at the top and bottom of the SCB card carrier. If that does not work, reinstall the SCB.The SCB has a reset switch on its faceplate above the LEDs. You normally do not use the reset switch. Pushing the reset switch results in a cold restart of the Packet Forwarding Engine, which causes a service interruption for a minute or two. To trip the reset switch, you must access it through a hole in the faceplate with a paper clip or other small probe.