Step 3: Switch SFM Mastership
Purpose
You can switch SFM mastership on M40e routers only. By default, the SFM in slot 0 (
SFM0) is the master and the SFM in slot 1 (SFM1) is the backup.To change the default master SFM, include the sfm statement at the [edit chassis redundancy] hierarchy level in the configuration. For more information, see the JUNOS System Basics Configuration Guide.
Action
To switch SFM mastership, use the following CLI command:
user@host>request chassis sfm master switch<no-confirm>Sample Output
user@host> request chassis sfm master switchwarning: Traffic will be interrupted while the PFE is re-initializedToggle mastership between system forwarding module? [yes,no] (no) yesSwitch initiated, use "show chassis sfm" to verifyThe following command output displays if you use the
no-confirmoption:user@host> request chassis sfm master switch no-confirmSwitch initiated, use "show chassis sfm" to verify