[Contents] [Prev] [Next] [Index] [Report an Error]


Performing a Swap Test on a Redundant SCG

CAUTION: Before performing a swap test, always check for bent pins in the midplane and check the SCG for stuck pins in the connector. Pins stuck in the component connector can damage other good slots during a swap test.


Action

To perform a swap test on a redundant SCG, follow these steps:

  1. Take the SCG offline by doing one of the following:
  1. Loosen the captive screws on the edges of the SCG faceplate.
  2. Grasp the SCG by the handle on the faceplate and slide it out of the chassis.
  3. Place the SCG on the antistatic mat.
  4. Remove the replacement SCG from its electrostatic bag.
  5. Carefully align the sides of the SCG with the guides in the SCG slot.
  6. Grasp the SCG by its handle and slide it straight into the chassis until it contacts the midplane.
  7. Tighten the captive screws on the corners of the SCG faceplate.
  8. Bring the SCG online by doing one of the following:
  1. Verify that the SCG is online by using the following CLI command:
  2. user@host> request chassis scg online slot number 
    
    
    

If the replaced SCG is online, the removed SCG has failed. Return the SCG as described in Return the Failed Component.


[Contents] [Prev] [Next] [Index] [Report an Error]