M7i Router Power Supplies

Two load-sharing, isolated power supplies are located at the bottom rear of the M7i router chassis. The router uses either AC or DC power. Figure 86 shows the M7i router power supplies and where they are installed in the chassis.

When the power supplies are installed and operational, they automatically share the electrical load.

For full redundancy, two power supplies are required. If a power supply stops functioning for any reason, the second power supply instantly begins providing all the power the router needs for normal functioning. The second power supply can provide full power indefinitely.


Figure 86: M7i Router Power Supplies

NOTE: When two power supplies are installed, at least one Routing Engine and one FPC must also be installed for both power supplies to power on. In the absence of this minimum load, only one power supply starts. (The router powers on and operates correctly with one power supply, but without the redundancy benefit of having a second power supply installed.)