Step 1: Display the Power Supply Hardware Information
Action
To display power supply hardware information, use the following CLI command:
user@host>show chassis hardwareSample Output
For M5, M10, M20, M40, and M40e routers:
user@host> show chassis hardwareHardware inventory:Item Version Part number Serial number DescriptionChassis 2003 M20Backplane REV 07 710-001517 AA7940Power Supply A Rev 02 740-001465 000497 ACPower Supply B Rev 01 740-001465 000001 AC[...Output truncated...]For M160 and T320 routers and T640 routing nodes:
user@host> show chassis hardwareItem Version Part number Serial number DescriptionChassis 47 M160Midplane REV 02 710-001245 AB4113FPM CMB REV 01 710-001642 AA9721FPM Display REV 01 710-001647 AA2995CIP REV 02 710-001593 AA9886PEM 0 Rev 01 740-001243 KJ35782 DCPEM 1 Rev 01 740-001243 kj35756 DC[...Output truncated...]What It Means
For all routers except the M160 and T320 routers and the T640 routing node, the command output displays the power supply slot number, revision level, part number, serial number, and the power supply type. When facing the back of the router, power supply A is located on the right and power supply B is located on the left.
For the M160 and T320 routers and the T640 routing node, the command output displays the power supply or PEM slot number, revision level, part number, serial number, and power supply type. When facing the back of the router, PEM 0 is located on the right and PEM 1 is located on the left.