Step 3: Display Power Supply Error Messages in the Chassis Daemon Log File
Action
To display power supply error messages in the
chassisdlog file, use the following CLI command:user@host>show log chassisd | match pemSample Output
user@host> show log chassisd | match pemJul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Amber LED Off [0x18]Jul 15 11:18:59 PEM#0 - Amber LED OffJul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Green LED Off [0x1a]Jul 15 11:18:59 PEM#0 - Green LED OffJul 15 11:18:59 CMB cmd to PEM#0 [0xf8], Blue LED Off [0x16]Jul 15 11:18:59 PEM#0 - Blue LED OffJul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Amber LED Off [0x18]Jul 15 11:18:59 PEM#1 - Amber LED OffJul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Green LED Off [0x1a]Jul 15 11:18:59 PEM#1 - Green LED OffJul 15 11:18:59 CMB cmd to PEM#1 [0xf9], Blue LED Off [0x16]Jul 15 11:18:59 PEM#1 - Blue LED OffJul 15 11:19:02 PEM#0 addedJul 15 11:19:02 reading PEM 0 initial stateJul 15 11:19:02 PEM#1 addedJul 15 11:19:02 reading PEM 1 initial stateJul 15 11:19:18 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breakerJul 15 11:19:18 CHASSISD_SNMP_TRAP: SNMP trap: FRU failure: jnxFruContentsIndex 2, jnxFruL1Index 2, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName PEM 1, jnxFruType 7, jnxFruSlot 2, jnxFruOfflineReason 2, jnxFruLastPowerOff 0, jnxFruLastPowerOn26221491, jnxFruPowerUpTime 1484Jul 15 11:19:23 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breakerJul 15 11:19:28 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breakerJul 15 11:19:33 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breakerJul 15 11:19:38 CHASSISD_PEM_INPUT_BAD: PEM 1 - INPUT FAIL, status bits: 0xf2, check breakerWhat It Means
The
chassisddatabase provides the date, time, and a component status message. Thechassisddatabase is dynamic. It is initialized at router startup and is updated when components are added or removed.