Step 1: Check the Power Supply Environmental Status
Action
To check the power supply environmental status, use the following JUNOS command-line interface (CLI) operational mode command:
user@host>show chassis environmentSample Output
For M5, M10, M20, and M40 routers:
user@host> show chassis environmentClass Item Status MeasurementPower Power Supply A OKPower Supply B Absent[...Output truncated...]user@host> show chassis environmentClass Item Status MeasurementPower Power Supply 0 OKPower Supply 1 Absent[...Output truncated...]For M40e, M160, M320 and T320 routers and T640 routing nodes:
user@host> show chassis environmentClass Item Status MeasurementPower PEM 0 OKPEM 1 OK[...Output truncated...]What It Means
The command output displays the status of both power supplies installed in the router.
For M5, M10, M7i, M10i, M20, and M40 routers, the command output displays the power supply slot number and status. The status can be
OK,Testing(during initial power-on),Failed, orAbsent. AFailedcondition triggers the red alarm LED on the craft interface.For M40e, M160, M320, and T320 routers and T640 routing nodes, the output displays the power supply slot number and status for the Power Entry Modules (PEMs). The status can be
OK,Absent, orCheck.Alternative Action
For the M40e, M160, M320, and T320 routers and the T640 routing node, to display the power supply status, use the following CLI command:
user@host>show chassis environment pemuser@host> show chassis environment pemPEM 0 status:State OnlineTemperature OKDC input OKDC output OKLoad Less than 20 percentVoltage:48.0 V input 69028 mV48.0 V fan supply 48839 mV5.0 V bias 5013 mV8.0 V bias 8253 mVPEM 1 status:State OnlineTemperature OKDC input OKDC output OKLoad Less than 20 percentVoltage:48.0 V input 69307 mV48.0 V fan supply 49170 mV5.0 V bias 4991 mV8.0 V bias 8263 mVFor each PEM, the command output displays the slot number, status, temperature, DC input and output, load percentage, and voltage. You can display the status of a particular power supply by specifying the
slotnumber.For T320 routers and T640 routing nodes, the command output displays the PEM slot number, status, temperature, DC input status, and DC output for each Flexible PIC Concentrator (FPC), SONET Clock Generator (SCG), Control Board, and Switch Interface Board (SIB). You can display the status of a particular power supply by specifying the
slotnumber.user@host> show chassis environment pemPEM 1 status:State OnlineTemperature 33 degrees C / 91 degrees FDC input: OKDC Output: Voltage Current Power LoadFPC 0 53783 3368 181 24FPC 1 0 0 0 0FPC 2 0 0 0 0FPC 3 0 0 0 0FPC 4 54041 3462 187 24FPC 5 53883 5187 279 37FPC 6 0 0 0 0FPC 7 0 0 0 0SCG/CB/SIB 54066 4031 217 18