Step 1: Monitor the PCG Environmental Status
Action
To monitor the PCG environment status, use the following JUNOS software command-line interface (CLI) command:
user@host>show chassis environmentSample Output
user@host> show chassis environmentClass Item Status MeasurementPower PEM 0 OKPEM 1 OKTemp PCG 0 OK 41 degrees C / 105 degrees FPCG 1 OK 39 degrees C / 102 degrees F[...Output truncated...]What It Means
The command output displays the status and temperature for each PCG.
Alternative Action
If there is a problem with the PCG status, you can display more detailed PCG environmental information with the following CLI command:
user@host>show chassis environment pcgThe command output is as follows:
user@host> show chassis environment pcgPCG 0 status:State Online - PFE clock sourceTemperature 41 degrees C / 105 degrees FFrequency:Setting 125.00 MHzMeasurement 125.03 MHzPower:3.3 V 3266 mV5.0 V bias 4981 mV8.0 V bias 8168 mVCMB Revision 12PCG 1 status:State OnlineTemperature 39 degrees C / 102 degrees FFrequency:Setting 125.00 MHzMeasurement 125.03 MHzPower:3.3 V 3271 mV5.0 V bias 4971 mV8.0 V bias 8175 mVCMB Revision 12The command output displays the status for each PCG slot 0 and 1. The operating status can be
Present,Online,Offline, orEmpty. IfOnline, it can be the current PFE clock source or backup. The command output displays the temperature of the air flowing past the PCG and the frequency setting and measurement for the PCG. The command output also displays information about the PCG power supplies and the revision level of the chassis management bus (CMB) slave.