Step 3: Display PCG Error Messages in the Chassis Daemon Log File
Action
To display the PCG error messages in the chassis daemon (
chassisd)log file, use the following CLI command:user@host>show log chassisdSample Output
user@host> show log chassisdJun 11 20:31:17 FPC 7 - Disable Power [addr 0x17 cmd 0x10]Jun 11 20:31:17 CMB readback FPC 7 [0xf7, 0xf2] -> 0x26Jun 11 20:31:17 power disable verified, FPC 7Jun 11 20:31:17 CHASSISD_IFDEV_DETACH: ifdev_detach(7)Jun 11 20:31:17 ifd so-7/0/0 marked as goneJun 11 20:31:19 PCG 0 set alarm 0x3Jun 11 20:31:19 alarm op fru 1 op 1 reason 3Jun 11 20:31:19 send: yellow alarm set, class 100 obj 110 reason 3Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Disable Power [0x10]Jun 11 20:31:19 PCG 0 - Disable Power [addr 0x2 cmd 0x10]Jun 11 20:31:19 CMB readback PCG 0 [0xe2, 0xf2] -> 0x6Jun 11 20:31:19 power disable verified, PCG 0Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Blue LED Off [0x16]Jun 11 20:31:19 PCG 0 - Blue LED OffJun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Green LED Off [0x1a]Jun 11 20:31:19 PCG 0 - Green LED OffJun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Amber LED Off [0x18]Jun 11 20:31:19 PCG 0 - Amber LED OffJun 11 20:31:19 mcs_intr_handler fpm_mcsfd 10Jun 11 20:31:19 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x0Jun 11 20:31:19 bp_handle_button_intr button status 0x0Jun 11 20:31:21 reading FPC 0 initial stateJun 11 20:31:21 CMB readback FPC 0 [0xf0, 0xff] -> 0xcJun 11 20:31:21 reading FPC 0 ideepromJun 11 20:31:21 reading FPC 1 initial stateJun 11 20:31:21 CMB readback FPC 1 [0xf1, 0xff] -> 0xcJun 11 20:31:21 reading FPC 1 ideepromJun 11 20:31:21 reading FPC 2 initial stateJun 11 20:31:21 CMB readback FPC 2 [0xf2, 0xff] -> 0xcJun 11 20:31:21 reading FPC 2 ideepromJun 11 20:31:21 reading FPC 6 initial stateJun 11 20:31:21 CMB readback FPC 6 [0xf6, 0xff] -> 0xcJun 11 20:31:21 reading FPC 6 ideepromJun 11 20:31:21 reading FPC 7 initial stateJun 11 20:31:21 CMB readback FPC 7 [0xf7, 0xff] -> 0xcJun 11 20:31:21 reading FPC 7 ideepromJun 11 20:31:21 gen_sfm_wait_mask 0x0Jun 11 20:31:21 ...power sequencer started...What It Means
The
chassisddatabase provides the date, time, and a component status message. Thechassisddatabase is dynamic. It is initialized at router startup and is updated when components are added or removed.