Monitoring FPCs
You monitor and maintain Flexible PIC Concentrators (FPCs) to connect Physical Interface Cards (PICs) to the rest of the router so that incoming packets are forwarded across the midplane to the appropriate destination ports. (See Table 44.)
Table 44: Checklist for Monitoring FPCs
- (M40e, M160, M320, and T320 routers and T640 routing node only) Check FPC Status and Temperature
Or, physically check the FPC LEDs on the Front Panel Module (FPM).
The fuses for the and FPCs are located in the rear of the midplane behind the power supply in slot
PEM0.
- M20 Internet router—With the FPC in horizontal position, look on the top back right of the FPC.
- M40 Internet router—With the FPC in vertical position, look on the back left side of the FPC.
- M40e and M160 routers—With the FPC in vertical position, look on the center right side of the FPC.
- For M320 routers—On an FPC3, the serial number ID label is located on the center of the right side. On an FPC2, the serial number label is located on the top PIC slot.
- For T320 routers—On an FPC3, the serial number ID label is located on the center of the right side. On an FPC1 and FPC2, the serial number ID label is located near the top PIC slot.
- For T640 routing nodes—On an FPC3, the serial number label is located on the center of the right side. On an FPC2, the serial number label is located near the top PIC slot.
See Return the Failed Component. Follow the procedure in the appropriate router hardware guide.