Step 1: Display the FIC Hardware Information

Action

To display the FIC hardware information, use the following CLI command:

user@host> show chassis hardware

Sample Output

user@host> show chassis hardware 
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                30512             M7i
Midplane         REV 04   710-008761   CB9213            M7i Midplane
Power Supply 0   Rev 02   740-008985   QB12884           DC Power Supply
Routing Engine   REV 09   740-009459   1000482742        RE-5.0
CFEB             REV 04   750-010112   CB8664            Internet Processor II
FPC 0                                                    E-FPC
FPC 1                                                    E-FPC
  PIC 2                   BUILTIN      BUILTIN           1x Tunnel
  PIC 3          REV 04   750-009099   CB9103            1x G/E, 1000 BASE

What It Means

The command output displays the hardware revision level, part number, serial number, and description for the FIC located at FPC 1 PIC 3.