Step 2: Display the CFEB Detailed Status

Action

To display more detailed CFEB status, use the following CLI command:

user@host> show chassis cfeb

Sample Output

user@host> show chassis cfeb
CFEB status:
Slot 0 information:
  State                                 Master
  Intake temperature                 29 degrees C / 84 degrees F
  Exhaust temperature                38 degrees C / 100 degrees F
  CPU utilization                     3 percent
  Interrupt utilization               0 percent
  Heap utilization                   10 percent
  Buffer utilization                 22 percent
  Total CPU DRAM                    128 MB
  Internet Processor II                 Version 1, Foundry IBM, Part number 164
  Start time:                           2004-09-28 03:07:54 PDT
  Uptime:                              9 days, 18 hours, 36 minutes, 15 seconds
Slot 1 information:
  State                                 Backup

What It Means

The command output displays the temperature of the air passing by the CFEB intake and exhaust, in degrees Centigrade. It displays the total percentage of CPU, interrupt, heap space, and buffer space being used by the CFEB processor, including the total DRAM available to the CFEB processor. The command output displays the time when the CFEB started running and how long the CFEB has been running. A short uptime can indicate that there is a CFEB problem.