[Contents] [Prev] [Next] [Index] [Report an Error]


Step 1: Check the PIC or FPC LED Status

Action

To view the PIC port status, look at the PIC or FPC LEDs. You can also use the show chassis fpc pic-status fpc-slot or the show chassis pic pic-slot number fpc-slot number CLI commands.

For M5, M10, and M20 routers, each port on each PIC has one LED, which is located on the PIC faceplate above the optical transceiver. Each LED has four different states, described in Table 71. If the cable is installed properly, the PIC port LED is green.

For M5 and M10 routers, if the Forwarding Engine Board (FEB) detects a PIC failure, it sends an alarm to the Routing Engine.


Table 71: M5, M10, and M20 Router PIC LEDs
Color
State
Description

Red

Fail

PIC is online but the link has failed.

Green

Normal

Port is functioning normally.

Yellow

Problem detected; still functioning

To track the problem, use the command-line interface (CLI).

None

Not enabled

Port is not enabled.


For M7i and M10i routers, check the LEDs on the PIC faceplates. Most PIC faceplates have an LED labeled STATUS. Some PICs have additional LEDs, often one per port. The meaning of the LED states differs for various PICs. Each PIC has an LED on the FIC labeled PICS ON/OFF that shows whether the PIC is online.

For M20 routers, if the FPC that houses the PIC detects a PIC failure, the FPC informs the System and Switch Board (SSB), which in turn sends an alarm to the Routing Engine.

For M40 routers, each FPC has two LEDs that report its status as OK or Fail. The LEDs are located below each FPC, on the craft interface. If there is a PIC failure, the FPC Fail LED lights.

For M40e, M160, and T320 routers and T640 routing nodes, each of the eight FPC slots in the router has two LEDs and an offline button located directly above it on the craft interface. The green LED labeled OK and the red LED labeled FAIL indicate the FPC status, as described in Table 72. The offline button, labeled with the FPC slot number (for example, FPC4), prepares the FPC for removal from the router when pressed. Press and hold the button for about 3 seconds until the FAIL LED lights.

Each FPC slot has two LEDs that indicate its status. The FPC LEDs, labeled FPC0 through FPC7, are located along the bottom of the craft interface. Table 72 describes the functions of the FPC LEDs. Each FPC also has a button that you use to take the FPC offline and bring it online. The button is located next to the FPC LEDs on the bottom of the craft interface.


Table 72: M40e, M160, and T320 Routers and T640 Routing Node FPC LEDs 
Label
Color
State
Description

OK

Green

On steadily

FPC is functioning normally.

Blinking

FPC is starting up.

FAIL

Red

On steadily

FPC has failed.



[Contents] [Prev] [Next] [Index] [Report an Error]