The jnxYellowAlarms, whose object identifier is {jnxCraftAlarms 2} contains the objects listed in Table 153.
Table 153: jnxYellowAlarms
Object
Object ID
Description
jnxYellowAlarmState
jnxYellowAlarms 1
Denotes the yellow alarm state on the craft interface
panel of the router chassis. This object contains one of the following
integer values:
other–1: The alarm state is unknown.
off–2: The yellow alarms are off. You can
turn off the yellow alarms using the Alarm Cutoff/Lamp Test button
on the craft interface panel of the router chassis.
on–3: The yellow alarms are on.
jnxYellowAlarmCount
jnxYellowAlarms 2
Shows the number of currently active and nonsilent yellow
alarms.
Note:
The value of this object is independent of the state of
the Alarm Cutoff/Lamp Test button.
jnxYellowAlarmLastChange
jnxYellowAlarms 3
Shows the value of the sysUp time when the state
of the yellow alarm last changed from on to off or vice versa. This
object returns 0 if the alarm state has not changed since
the sysUp time was reset last time, or if the value is unknown.