[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Defining a Discontinuity Check to Validate Delta Values (SRC
CLI)
You can configure a monitor to use a discontinuity check
to prevent sending false alarms when the value of the monitored object
is reset between two samples.
Use a discontinuity check when the sampling type
for a monitor is delta-value and the test
type is boolean or threshold. You define a variable, called a discontinuity
marker (a MIB object used to validate the delta, or difference, between
values). Typically, the marker object is of the type TimeTicks, DateAndTime,
or Timestamp.
To define a discontinuity check:
- Configure an SNMP alarm with the sample type set to delta-value.
See Configuring an SNMP Alarm on a C Series Controller (SRC CLI).
- From configuration mode, access the configuration statements
that configures a discontinuity check. For example, for an alarm named
ifErrorsDelta:
- [edit]
- user@host# edit snmp monitor alarm ifErrorsDelta
delta-discontinuity-check
- Specify the name or object identifier (OID) of the discontinuity
marker. For example:
- [edit snmp monitor alarm sequence-check ifErrorsDelta delta-discontinuity-check]
- user@host# set variable ifTable.ifEntry.ifLastChange
Related Topics
[Contents]
[Prev]
[Next]
[Index]
[Report an Error]